[Hletech] R290 Photovoltaic Direct Drive Triple Heating Pump Heating, Cooling, Domestic Hot Water ERP A+++
Support photovoltaic direct drive connection, the heat pump can directly use photovoltaic panels to output DC power for operation. Significantly increase the self use rate of rooftop photovoltaics, reduce dependence on mains electricity, save energy consumption expenses in the long run, and adapt to European households with existing photovoltaic systems. One machine meets three major needs: winter heating, summer cooling, and all-weather domestic hot water. Replace boilers, air conditioners, and multiple water heaters to save installation space and reduce total equipment investment. Using natural R290 propane refrigerant with extremely low GWP, it meets the EU F-Gas control requirements, avoids the risk of high GWP refrigerant elimination, and is a long-term sustainable HVAC solution for the European market. The full DC variable frequency compressor dynamically adjusts the load and maintains efficient operation under partial load conditions; ERP A++energy efficiency certification reduces energy consumption and carbon emissions.
| R290 photovoltaic direct drive variable frequency cold and hot water unit | ||||||
| Product Model:KFXLR- | 10I/R8ZBPS-G | 13I/R8ZBPS-G | 16II/R8ZBPS | 19II/R8ZBPS | ||
| Heating conditions Ambient temperature:7℃ 出水温度:35℃ |
heating capacity | W | 10000 | 12800 | 16000 | 19000 |
| Rated input power | W | 2350 | 2970 | 3720 | 4520 | |
| coefficient of performance | W/W | 4.25 | 4.31 | 4.30 | 4.20 | |
| Heating conditions Ambient temperature:7℃ outlet water temperature:45℃ |
heating capacity | W | 9960 | 12750 | 15940 | 18930 |
| input power | W | 2930 | 3695 | 4635 | 5635 | |
| coefficient of performance | W/W | 3.40 | 3.45 | 3.44 | 3.36 | |
| Heating conditions Ambient temperature:-12℃ outlet water temperature:41℃ |
heating capacity | W | 6275 | 8030 | 10040 | 11925 |
| input power | W | 2560 | 3240 | 4048 | 4928 | |
| coefficient of performance | W/W | 2.45 | 2.48 | 2.48 | 2.42 | |
| Cooling condition Ambient temperature:35℃ outlet water temperature:7℃ |
refrigeration capacity | W | 7310 | 9360 | 11700 | 13900 |
| input power | W | 2590 | 3280 | 4060 | 4960 | |
| coefficient of performance | W/W | 2.82 | 2.85 | 2.88 | 2.80 | |
| Cooling condition Ambient temperature:35℃ outlet water temperature:18℃ |
refrigeration capacity | W | 9140 | 11700 | 14620 | 17360 |
| Rated input power | W | 2610 | 3330 | 4180 | 5030 | |
| coefficient of performance | W/W | 3.50 | 3.51 | 3.50 | 3.45 | |
| Rated voltage/frequency | 220-240V 50Hz ~inverter~1N | 380-415V 50Hz ~inverter~3N | ||||
| Maximum input power/current | W/A | 3810/18 | 4800/22 | 6025/11 | 7325/13 | |
| Rated circulating water flow rate | m³/h | 1.72 | 2.20 | 2.80 | 3.30 | |
| Water side pressure loss | kPa | 25 | 30 | 35 | 40 | |
| scope of work | ℃ | refrigeration:20〜46℃;heating:-30〜21℃ | ||||
| Maximum outlet temperature | ℃ | 75 | 75 | 75 | 75 | |
| refrigerant | R290 | R290 | R290 | R290 | ||
| waterproof rating | IPX4 | IPX4 | IPX4 | IPX4 | ||
| Types of electric shock protection | I | I | I | I | ||
| Unit noise | dB(A) | 53 | 53 | 55 | 55 | |
| Dimensions (length x width x height) | mm | 1190×505×980 | 1190×505×980 | 1190×505×1375 | 1190×505×1375 | |
| circulating water pipe | pipe diameter | mm | DN25 | DN25 | DN25 | DN25 |
| Connection form of pipe mouth | female thread | female thread | female thread | female thread | ||
| unit weight | kg | 117 | 122 | 155 | 160 | |